Central Pylon SBE32-24 320175

Summary



TypeCTD
VendorSea-Bird Scientific (Sea-Bird Electronics)
Modelunlisted
S/N3216020-0175
ID Prefixctdgen
CORIOLIX IDsbe_32-24_000175
ClassOverTheSide
LocationSecondary CTD
Conditionexcellent
Configuration
Native Sample RateNone Hz
UDP Port(s)None None
EnabledFalse
 


Image Not Available
 
 

General Description



Central Pylon SBE32-24

 
 

Data Collection Specs

Native Data Feed
Signal Type
Communication Type
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Start Commands
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol
Source File Details
Path
Filename
Native Data Format
Native Data Description
Native Data Type
Start of Message Characters
End of Message Characters
Sample Data Message
Message Parser Format
Data Processing
Data Processing Script NoTransformation
Data Rates
Native Sample Rate None Hz
Shipboard Network Packet Rate None Hz
Ship to Shore Rate None Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address
Port None
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source
 

Parameters


Quantity
Plot Color
Parameter Full Name
Parameter Short Name
Parameter Standard Name
SAMOS Data Category
Description
Processing Status
Processing Symbol
Diagnostic
IOOS Category
Units
Data Type
Gross Minimum Value
Gross Maximum Value
Recommended Minimum Value
Recommended Maximum Value
Global Minimum Value
Global Maximum Value
Local Minimum Value
Local Maximum Value
Lower Detection Limit
Saturated Value
Bad Data Value
Resolution
Accuracy
Precision
Binning Type
Online Display Format
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power None - None V DC
Ideal Power None V DC
Operating Current None - None mA @ None V DC
Analog Output None - None
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth None - 6800 m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset None seconds
Physical Status
Current Location in storage
Current Status not in use
Physical Condition excellent
22Sep2025 arrived fully repaired at GSO from SBE. 06Aug2025 Approval finally went to SBE. 30Jun2025 Quote for Approval $15808.75! 22May2025 sent to SBE for repairs RMA 1005523954. 07May2025 EN729_MendenDeuer showing errors - "Unsupported modem message: 06 2D 06 from SBECarousel" and inoperable. April2025 and before: Removed from the spare 24pl CTD frame on Endeavor. Stored in the hold, ready for installation in a primary CTD frame while 0048 gets serviced. March 2025 and before: Installed the spare 24pl CTD frame on Endeavor. Nov 2023: Installed in a CTD frame which is in the MLB.
Physical Configuration
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level spare
Enabled False
Vessel Installation Location
Vessel
Vessel Location Secondary CTD
Location Coordinates (meters)
Sensor Orientation vertical
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Sep 24 2025 13:28:09     Butler, Lynne     sensor specs update     vessel changed from [Endeavor] to []    
Sep 24 2025 13:13:34     Butler, Lynne     sensor specs update     condition_details changed from [Quote for Approval $ ... which is in the MLB] to [22Sep2025 arrived fu ... which is in the MLB.]    
Sep 24 2025 13:13:34     Butler, Lynne     sensor specs update     condition changed from [inoperable] to [excellent]    
Sep 24 2025 13:13:34     Butler, Lynne     sensor specs update     current_status changed from [repair in progress] to [not in use]    
Sep 24 2025 13:13:34     Butler, Lynne     sensor specs update     current_location changed from [repair/calibration] to [in storage]    
Jul 16 2025 09:17:25     Butler, Lynne     sensor specs update     sensor_orientation changed from [] to [vertical]    
Jul 16 2025 09:17:25     Butler, Lynne     sensor specs update     location_text changed from [] to [Secondary CTD]    
Jul 16 2025 09:17:25     Butler, Lynne     sensor specs update     condition_details changed from [As of April 2025 and ... which is in the MLB] to [Quote for Approval $ ... which is in the MLB]    
Jul 16 2025 09:17:25     Butler, Lynne     sensor specs update     depth_max_meters changed from [5000] to [6800]    
Jul 16 2025 09:05:11     Butler, Lynne     sensor specs update     condition changed from [good] to [inoperable]    
Jul 16 2025 09:05:11     Butler, Lynne     sensor specs update     current_status changed from [not in use] to [repair in progress]    
Jul 16 2025 09:05:11     Butler, Lynne     sensor specs update     current_location changed from [on vessel] to [repair/calibration]    
Jul 16 2025 09:05:11     Butler, Lynne     sensor specs update     serial_number changed from [320175] to [3216020-0175]    
May 07 2025 13:05:00     Clarke, Bonny     issue     On cast EN729_006, bottle one fired, then 2 and 3 did not fire. All other bottles 'fired' in the software. Upon recover none of the bottles had actually fired. Bottles 2 and 3 returned ' Unsupporte    
Apr 21 2025 23:31:08     Butler, Lynne     sensor specs update     use_level changed from [] to [spare]    
Apr 21 2025 23:31:08     Butler, Lynne     sensor specs update     condition_details changed from [Installed in a CTD f ... e MLB as of Nov 2023] to [As of April 2025 and ... which is in the MLB]    
Apr 21 2025 23:31:08     Butler, Lynne     sensor specs update     current_location changed from [] to [on vessel]    
Nov 05 2024 21:54:03     Nahorniak, Jasmine     sensor specs update     processing_script changed from [] to [NoTransformation]    
Nov 05 2024 21:54:03     Nahorniak, Jasmine     sensor specs update     model changed from [unknown] to [unlisted]    
Jul 27 2024 21:02:21     Clarke, Bonny     renamed sensor     Changed sensor ID from sbe_sbe32-24_320175 to sbe_32-24_000175.    
Jul 25 2024 00:09:49     Clarke, Bonny     renamed sensor     Changed sensor ID from SBE_SBE32-24_320175 to sbe_sbe32-24_320175.    
Jul 25 2024 00:08:56     Clarke, Bonny     sensor specs update     sensor_name changed from [Central Pylon SBE32-24 0175] to [Central Pylon SBE32-24 320175]    
Jul 25 2024 00:08:14     Clarke, Bonny     renamed sensor     Changed sensor ID from centpy000175 to SBE_SBE32-24_320175.    
Jun 06 2024 15:53:27     Butler, Lynne     sensor specs update     sensor_name changed from [Central Pylon SBE32-24] to [Central Pylon SBE32-24 0175]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     condition_details changed from [] to [Installed in a CTD f ... e MLB as of Nov 2023]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     condition changed from [] to [good]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     current_status changed from [] to [not in use]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     acquire_condition changed from [] to [excellent]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     responsible_party changed from [] to [URI Marine Technicians]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     owner changed from [] to [URI]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     depth_max_meters changed from [None] to [5000]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     power_current_type changed from [AC] to [DC]    
Nov 30 2023 22:32:24     Butler, Lynne     sensor specs update     serial_number changed from [175] to [320175]    
Nov 06 2023 16:39:43     Clarke, Bonny     renamed sensor     Changed sensor ID from CENTPY000175 to centpy000175.    
May 28 2023 19:18:58     Clarke, Bonny     sensor specs update     serial_number changed from [SBE32-24] to [175]    
May 28 2023 19:08:09     Clarke, Bonny     new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C:
 
Calibration
 
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
 
 
User Guides & Documents

Date Version Author Type Document Access
Sep 16 2025        SBE   repair_sheet   1005523954_00000100_SBEServiceReport_SBE32_16020-0175_16Sep25_Repairs.pdf
Sep 09 2025        SBE   repair_sheet   SBE32_16020-0175_09Sep25_HiPressNotDone_PTest.pdf
Jun 01 2016        SBE   datasheet   SBE 32 datasheet
Sep 01 2023   A     SBE   user_manual   SBE32 user manual
 
 
Ownership

Quantity Value
Owner URI
Responsible Party URI Marine Technicians
Purchase Date
Acquire Date
Acquire Condition excellent
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Sea-Bird Scientific (Sea-Bird Electronics)
Website http://www.seabird.com
Phone +1 425 643 9866
Email techsupport@seabird.com
Shipping Sea-Bird Scientific, 13431 NE 20th Street, Bellevue, Washington 98005, USA
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA