Air Temperature and Relative Humidity

Summary



TypeMet Station
VendorR.M. Young Company
ModelYoung 41382 relative humidity and temperature probe
S/N035269
ID Prefixhygrom
CORIOLIX IDrmy_temprh_035269
ClassAtmospheric
LocationBow Mast
Condition
Configuration
Native Sample Rate1.0 Hz
UDP Port(s)17011 16000
EnabledTrue
 
 
 

General Description



R. M. Young Air Temperature and Relative Humidity sensor. It can be installed above the Pilot House Roof near the main mast or on the Bow mast. Model 41382VC. Full Serial Number TS000035269.

 
 

Data Collection Specs

Native Data Feed
Signal Type Analog
Communication Type
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol
Source File Details
Path
Filename
Native Data Format
Native Data Description
Native Data Type text
Start of Message Characters
End of Message Characters
Sample Data Message $WIMWV,042,R,005.90,N,00*46^$WIXDR,C, 21.7,C,TEMP,H,089,P,RH,P,1012,mB,BARO*36
Message Parser Format ['^\WWIMWV,(\d+)?,R,(\d+\.\d+)?,N,\d\d\*(?P<checksum_1>[0-9A-F]{2})\W*\WWIXDR,C,\s*(?P<air_temperature>\-?\d+\.\d+),C,TEMP,H,(?P<relative_humidity>\d+),P,RH,P,\s*(?P<air_pressure>\d+),mB,BARO\*(?P<checksum_2>[0-9A-F]{2})$']
Data Processing
Data Processing Script NoTransformation
Data Rates
Native Sample Rate 1.0 Hz
Shipboard Network Packet Rate 1.0 Hz
Ship to Shore Rate 1.0 Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address 192.167.0.255
Port 17011
Packet Size None
Transformed Data Ethernet Distribution
IP Address 192.167.0.255
Port 16000
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source
 

Parameters


Quantity Air Temperature Bow (degrees_C)
Plot Color
 
Parameter Full Name Air Temperature Bow
Parameter Short Name Air Temperature Bow
Parameter Standard Name XXXXXXXX
SAMOS Data Category Air Temperature
Description ***Measured with a 1000 ohm Platinum RTD temperature sensor. Measurement range is from -50 to 50 degrees Celsius with an accuracy of 0.3 degrees Celsius.
Processing Status raw
Processing Symbol air_temperature
Diagnostic False
IOOS Category Meteorology
Units degrees_C
Data Type double
Gross Minimum Value None degrees_C
Gross Maximum Value None degrees_C
Recommended Minimum Value None degrees_C
Recommended Maximum Value None degrees_C
Global Minimum Value -50.0 degrees_C
Global Maximum Value 50.0 degrees_C
Local Minimum Value None degrees_C
Local Maximum Value None degrees_C
Lower Detection Limit 0.3 degrees_C
Saturated Value 50.0 degrees_C
Bad Data Value 50.0 degrees_C
Resolution None degrees_C
Accuracy +/- None degrees_C
Precision None degrees_C
Binning Type linear
Online Display Format 5.2f
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power None - None V AC
Ideal Power None V AC
Operating Current None - None mA @ None V AC
Analog Output None - None
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth None - None m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset 0.0 seconds
Physical Status
Current Location installed
Current Status in use
Physical Condition
DDMmm202Y Installed on bow mast. 12Dec2023 Last calibration/service.
Physical Configuration
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog Port
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled True
Vessel Installation Location
Vessel Endeavor
Vessel Location Bow Mast
Location Coordinates (meters)
Sensor Orientation
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Oct 12 2024 14:32:43     Butler, Lynne     sensor specs update     sensor_name changed from [Air temperature and relative humidity] to [Air Temperature and Relative Humidity]    
Oct 12 2024 14:15:07     Butler, Lynne     sensor specs update     description changed from [RM Young Air temperature and humidity sensor] to [R. M. Young Air Temp ... Number TS000035269.]    
Oct 12 2024 14:11:53     Butler, Lynne     sensor specs update     condition_details changed from [] to [DDMmm202Y Installed ... calibration/service.]    
Sep 11 2024 18:49:58     Nahorniak, Jasmine     sensor specs update     native_type changed from [] to [text]    
Jan 09 2024 19:00:22     Clarke, Bonny     sensor specs update     location_text changed from [Main Lab] to [Bow Mast]    
Jan 09 2024 19:00:22     Clarke, Bonny     sensor specs update     enabled changed from [False] to [True]    
Jan 09 2024 19:00:22     Clarke, Bonny     sensor specs update     current_status changed from [not in use] to [in use]    
Jan 09 2024 19:00:22     Clarke, Bonny     sensor specs update     current_location changed from [on vessel] to [installed]    
Jan 02 2024 19:41:42     Clarke, Bonny     renamed sensor     Changed sensor ID from rmy_airtrh_035269 to rmy_temprh_035269.    
Jan 02 2024 19:40:33     Clarke, Bonny     renamed sensor     Changed sensor ID from airtrh035269 to rmy_airtrh_035269.    
Dec 20 2023 16:32:47     Clarke, Bonny     sensor specs update     last_cal_date changed from [2023-01-18 00:00:00+00:00] to [2023-12-12 00:00:00+00:00]    
Dec 20 2023 16:32:47     Clarke, Bonny     sensor specs update     location_text changed from [RM Young] to [Main Lab]    
Dec 20 2023 16:32:47     Clarke, Bonny     sensor specs update     current_status changed from [calibration in progress] to [not in use]    
Dec 20 2023 16:32:47     Clarke, Bonny     sensor specs update     current_location changed from [repair/calibration] to [on vessel]    
Dec 13 2023 18:01:19     Clarke, Bonny     sensor specs update     text_regex_format changed from [] to [['^\WWIMWV,(\d+)?,R, ... um_2>[0-9A-F]{2})$']]    
Dec 13 2023 18:01:19     Clarke, Bonny     sensor specs update     sample_data_message changed from [] to [$WIMWV,042,R,005.90, ... RH,P,1012,mB,BARO*36]    
Nov 20 2023 17:29:18     Clarke, Bonny     sensor specs update     location_text changed from [Bow Met Stn] to [RM Young]    
Nov 20 2023 17:29:18     Clarke, Bonny     sensor specs update     enabled changed from [True] to [False]    
Nov 20 2023 17:29:18     Clarke, Bonny     sensor specs update     current_status changed from [in use] to [calibration in progress]    
Nov 20 2023 17:29:18     Clarke, Bonny     sensor specs update     current_location changed from [installed] to [repair/calibration]    
Nov 20 2023 17:26:00     Clarke, Bonny     relocation     Sent to RM Young for yearly calibration    
Nov 09 2023 03:59:25     Nahorniak, Jasmine     sensor specs update     transmit_port changed from [None] to [17011]    
Nov 09 2023 03:59:25     Nahorniak, Jasmine     sensor specs update     transmit_ip changed from [] to [192.167.0.255]    
Nov 06 2023 16:32:13     Clarke, Bonny     sensor specs update     enabled changed from [False] to [True]    
Nov 06 2023 16:32:13     Clarke, Bonny     sensor specs update     acquire_date changed from [2023-01-18 16:19:00+00:00] to [2023-01-18 00:00:00+00:00]    
Oct 12 2023 12:42:54     Clarke, Bonny     sensor specs update     model changed from [unknown] to [Young 41382 relative ... nd temperature probe]    
Oct 12 2023 12:38:42     Clarke, Bonny     sensor specs update     last_cal_date changed from [2022-12-08 00:00:00+00:00] to [2023-01-18 00:00:00+00:00]    
Oct 12 2023 12:36:34     Clarke, Bonny     sensor specs update     location_text changed from [] to [Bow Met Stn]    
Oct 12 2023 12:36:34     Clarke, Bonny     sensor specs update     current_status changed from [not in use] to [in use]    
Oct 12 2023 12:36:34     Clarke, Bonny     sensor specs update     current_location changed from [on vessel] to [installed]    
Aug 01 2023 22:21:40     Nahorniak, Jasmine     sensor specs update     time_source changed from [vessel_time_server] to []    
Aug 01 2023 22:21:40     Nahorniak, Jasmine     sensor specs update     model changed from [] to [unknown]    
Aug 01 2023 22:21:40     Nahorniak, Jasmine     sensor specs update     sensor_prefix changed from [] to [metstn]    
May 23 2023 18:48:44     Clarke, Bonny     new sensor     Initial submission of sensor metadata.    
Mar 10 2023 16:19:00     Clarke, Bonny     relocation     Sensor sent to RM Young for repairs    
Feb 15 2023 16:26:00     Clarke, Bonny     repair     Sensor repaired at facility    
Feb 01 2023 16:19:00     Clarke, Bonny     damaged     Sensor wired wrong upon installation. Damage required manufacturer repairs.    
Jan 18 2023 16:19:00     Clarke, Bonny     purchase/acquire         
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C: test001
 
Calibration
  12 months Dec 12 2023 Dec 12 2024
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
Dec 12 2023           cal_file   temprh35269 2023 cal cert
Jan 18 2023           cal_file   2023 airtemprh 035269
 
 
User Guides & Documents

Date Version Author Type Document Access
Feb 20 2023           repair_sheet   2023 airtemprh035269 repair sheet
Nov 20 2023           form   Cal RMA 2023
Jan 01 1998   1/98     R.M. Young Company   brochure   Gill Multi-Plate Radiation Shield Brochure
        R.M. Young Company   sensor_image   Gill Multi-Plate Radiation Shield Photo
   REV C01211     R.M. Young Company   instruction_sheet   Model 41003 Instruction Sheet
Apr 01 2000   REV 04-00     R.M. Young Company   instruction_sheet   Model 41372/43372 Instructions
   F111215     R.M. Young Company   instruction_sheet   RMY 41382VC Instruction Sheet
 
 
Ownership

Quantity Value
Owner URI
Responsible Party URI Marine Technicians
Purchase Date
Acquire Date Jan 18 2023
Acquire Condition
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company R.M. Young Company
Website http://www.youngusa.com
Phone +1 231 946 3980
Email service@youngusa.com
Shipping R.M. Young Company, Attn: Service Dept / RMA # ___ , 2801 Aero Park Drive, Traverse City, Michigan 49686, USA
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
Data Visualization

Time-Series Plots
   Flowthrough
   Meteorological
   Navigation
   Combination
   Custom
Charting Tools
 
Data Access

Data Structure
Quality Flags
Long-term Archive (R2R)
Data Download
   Full Resolution
   Binned Data
Web Services
   Direct Access Overview
   RESTful API
   ERDDAP
Software Tools
   Python Tools
   Matlab Tools
   R Tools
   ArcGIS Tools
 
Science Party Tools

Cruise & Participants Lists
Event Log
 
OSU logo NSF logo RCRV logo