PAR QSP-2350 70709

Summary



TypePAR Meter
VendorBiospherical Instruments Inc.
ModelBiospherical Instruments QSP-2350 underwater PAR sensor
S/N70709
ID Prefixparqsp
CORIOLIX IDradiom_70709
ClassOverTheSide
LocationPrimary CTD
Conditiongood
Configurationhose-clamped up high on a recovery rod
Native Sample RateNone Hz
UDP Port(s)None None
EnabledTrue
 
 
 

General Description



QSP-2350 70709 scalar underwater PAR sensor with compressed analog output

 
 

Data Collection Specs

Native Data Feed
Signal Type
Communication Type
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Start Commands None
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol
Source File Details
Path
Filename
Native Data Format
Native Data Description
Native Data Type
Start of Message Characters
End of Message Characters
Sample Data Message
Message Parser Format
Data Processing
Data Processing Script
Data Rates
Native Sample Rate None Hz
Shipboard Network Packet Rate None Hz
Ship to Shore Rate None Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address
Port None
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source
 

Parameters


Quantity
Plot Color
Parameter Full Name
Parameter Short Name
Parameter Standard Name
SAMOS Data Category
Description
Processing Status
Processing Symbol
Diagnostic
IOOS Category
Units
Data Type
Gross Minimum Value
Gross Maximum Value
Recommended Minimum Value
Recommended Maximum Value
Global Minimum Value
Global Maximum Value
Local Minimum Value
Local Maximum Value
Lower Detection Limit
Saturated Value
Bad Data Value
Resolution
Accuracy
Precision
Binning Type
Online Display Format
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power None - None V AC
Ideal Power None V AC
Operating Current None - None mA @ None V AC
Analog Output None - None
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth None - 2000 m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset None seconds
Physical Status
Current Location installed
Current Status in use
Physical Condition good
On 24pl CTD 0712
Physical Configuration hose-clamped up high on a recovery rod
Software Version
Software Configuration Use in conjunction w/ CTD SBE Seasave
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled True
Vessel Installation Location
Vessel Endeavor
Vessel Location Primary CTD
Location Coordinates (meters)
Sensor Orientation vertical up
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Sep 09 2024 15:50:06     Butler, Lynne     sensor specs update     enabled changed from [False] to [True]    
Sep 09 2024 15:50:06     Butler, Lynne     sensor specs update     configuration changed from [] to [hose-clamped up high on a recovery rod]    
Aug 26 2024 21:56:58     Butler, Lynne     sensor specs update     sensor_name changed from [PAR QSP2350 70709] to [PAR QSP-2350 70709]    
Aug 26 2024 21:40:25     Butler, Lynne     sensor specs update     last_cal_date changed from [2024-04-10 00:00:00+00:00] to [2023-06-07 00:00:00+00:00]    
Aug 26 2024 21:40:25     Butler, Lynne     sensor specs update     location_text changed from [Main Lab] to [Primary CTD]    
Aug 26 2024 21:40:25     Butler, Lynne     sensor specs update     condition_details changed from [] to [On 24pl CTD 0712]    
Aug 26 2024 21:40:25     Butler, Lynne     sensor specs update     current_status changed from [not in use] to [in use]    
Aug 26 2024 21:40:25     Butler, Lynne     sensor specs update     current_location changed from [on vessel] to [installed]    
Aug 26 2024 21:40:25     Butler, Lynne     sensor specs update     description changed from [QSP-2350 70513 scala ... ressed analog output] to [QSP-2350 70709 scala ... ressed analog output]    
Aug 26 2024 21:40:25     Butler, Lynne     sensor specs update     sensor_name changed from [PAR QSP2350 70513] to [PAR QSP2350 70709]    
Aug 26 2024 21:38:05     Butler, Lynne     new sensor     Copied sensor metadata from radiom_70513 with modified serial number 70709.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C:
 
Calibration
  18 months Jun 07 2023 Dec 07 2024
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
Jun 07 2023        Biospherical   cal_file   BiosphericalPAR_QSP2350_70709_07Jun23_CalScanned.pdf
 
 
User Guides & Documents

Date Version Author Type Document Access
Aug 27 2024        Claire Mayorga   sensor_image   PAR QSP2350_70513 Photo
 
 
Ownership

Quantity Value
Owner URI
Responsible Party URI Marine Technicians
Purchase Date
Acquire Date
Acquire Condition excellent
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Biospherical Instruments Inc.
Website http://www.biospherical.com
Phone +1 619 686 1888
Email support@biospherical.com
Shipping Biospherical Instruments Inc., 5340 Riley St., San Diego, CA 92110, USA
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA